Aiwa JAX-S5 Service Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
CX-JN10
1919
CD SECTION
Note:
1. CD Block is basically designed to operate without adjustment. Therefore,
check each item in order given.
2. Use YEDS-18 (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-CURVE CHECK
Procedure :
1. Connect an oscilloscope to TP (FE) and TP (VC).
2. Turn the power on.
3. Load a disc (YEDS-18) and actuate the focus search. (In
consequence of open and close the disc tray, actuate the focus
search)
4. Confirm that the oscilloscope waveform (S-curve) is
symmetrical between A and B. And confirm peak to peak level
within 3 ± 0.5 Vp-p.
Note: Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF LEVEL CHECK
Procedure :
1. Connect an oscilloscope to TP (RF) and TP (VC).
2. Turn the power on.
3. Load a disc (YEDS-18) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
BD board
Oscilloscope
TP(FE)
TP(VC)
symmetry
S-curve waveform
within 3
±
0.5Vp-
p
A
B
TP(RF)
BD board
oscilloscope
TP(VC)
Note: Clear RF signal waveform means that the shape “ ” can be clearly
distinguished at the center of the waveform.
Connecting Location: BD board
RF signal waveform
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.3
±
0.3Vp-
p
TP (VC)
TP (RF)
TP (FE)
IC721
– BD Board (Conductor side) –
SECTION 5
ELECTRICAL ADJUSTMENTS