1. Tape Speed Adjustment (DECK 2)
Settings : • Test tape : TTA–100
• Test point : TP5 (Lch), TP6 (Rch)
• Adjustment location : SFR1
Method : Play back the test tape and adjust SFR1 so that the
frequency counter reads 3000Hz ± 5Hz (FWD) and
± 45Hz (REV) with respect to forward speed.
2. Head Azimuth Adjustment (DECK 1, DECK 2)
Settings : • Test tape : TTA–300
• Test point : TP5 (Lch), TP6 (Rch)
• Adjustment location : Head azimuth
adjustment screw
Method : Play back (FWD) the 8kHz signal of the test tape
and adjust screw so that the output becomes maximum.
Next, perform on REV PLAY mode.
1. Clock Frequency Check
Settings : • Test point : TP2 (CLK)
Method : Set to AM 1710kHz and check that the test point is
2160kHz ± 45Hz.
2. AM VT Check
Settings : • Test point : TP1 (VT)
Method : Set to AM 1710kHz and check that the test point is less
than 8.5V. Then set to AM 530kHz and check that the
test point is more than 0.6V.
3. AM Tracking Adjustment
Settings : • Test point : TP5 (Lch), TP6 (Rch)
• Adjustment location : L951(1/3)
Method : Set to AM 1000kHz and adjust L951(1/3) so that the test
point becomes maximum.
4. FM VT Adjustment
Settings : • Test point : TP1 (VT)
• Adjustment location : L906
Method : Set to FM 108.0MHz and adjust L906 so that the test
point becomes 7.0V±0.1V.
5. FM Tracking Adjustment
Settings : • Test point : TP5(Lch), TP6(Rch)
• Adjustment location : L903
Method : Set to FM 87.5 MHz and adjust L903 so that the test
point is less than 9.0dBµV.
6. AM IF Adjustment
Settings : • Test point : TP5(Lch), TP6(Rch)
• Adjustment location :
L802..............................450kHz
7. DC Balance / Mono Distortion Adjustment
Settings : • Test point : TP3, TP4 (DC Balance)
: TP5 (Lch), TP6 (Rch) (Distortion)
• Adjustment location : L801
• Input level : 60dBµV
Method : Set to FM 98.0MHz and adjust L801 so that the voltage
between TP3 and TP4 becomes 0V±300mV.
Then check that the distortion is less than 1.2%
< TUNER SECTION >
ADJUSTMENT <TUNER / DECK / FRONT>
< DECK SECTION >
3. PB Frequency Response Check (DECK 1, DECK 2)
Settings : • Test tape : TTA–330
• Test point :TP5(Lch), TP6(Rch)
Method : Play back the 315Hz and 8kHz signals of the test
tape and check that the output ratio of the 10kHz
signal with respect to that of the 315Hz signal is
0dB ± 5dB.
4. REC/PB Frequency Response Adjustment (DECK 2)
Settings : • Test tape : TTA–602
• Test point : TP5(Lch), TP6(Rch)
• Adjustment location : SFR451(Lch)
SFR452(Rch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at the TP5,
TP6 becomes 10mV. Record and play back the 1kHz
and 8kHz signal and adjust SFRs so that the output of
the 8kHz signals is 0dB ± 1dB with respect to that of the
1kHz signal.
5. REC/PB Sensitivity Check (DECK 2)
Settings : • Test tape : TTA–602
• Test point : TP5(Lch), TP6(Rch)
• Input signal : 1kHz (LINE IN)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at TP5, TP6
becomes 80mV. Record and play back the 1kHz signals
and check that the output is –1dB ± 3.5dB.
6. PB Sensitivity Check (DECK 1, DECK 2)
Settings : • Test tape : TTA–200
• Test point :TP5 (Lch), TP6 (Rch)
Method : Play back the test tape and check that the output level of
the test point is 110mV ± 3dB.
< FRONT SECTION >
1. µ-CON OSC Adjustment
Settings : • Test point : TP7 (K-SCAN) and TP8 (GND)
• Adjustment location : L151
Method : Insert AC plug while pressing tuner function key and
power key. Adjust L151 so that the frequency at the test
point is 141.67Hz ± 0.14Hz.