Aiwa NSX-D77 User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
1. Clock Frequency Check
Settings : Test point : TP6 (CLK)
Method : Set to AM 1710kHz<U,LH>, 1602kHz<HS>
and check that the test point is 2160kHz ± 45Hz
<U,LH>, 2052kHz ± 45Hz<HS> .
2. AM VT Check
Settings : Test point : TP3 (VT)
Method : Set to AM 1710kHz<U,LH>, 1602kHz<HS>
and AM 530kHz<U,LH>, 531kHz<HS> and
check that the test point is less than 8.5V
(1710kHz)<U,LH>, 8.0V(1692kHz)<HS>
and more than 0.6V(530kHz,531kHz)
3. AM Tracking Adjustment
Settings : Test point : TP7(Lch), TP8(Rch)
Adjustment location :
L951(1/3)........................ 999kHz
Method : Set to AM 999kHz and adjust
L951(1/3) so that the test point is max.
4. FM VT Check
Settings : Test point : TP3 (VT)
Method : Set to FM 108.0MHz and check that the test
point is less than 8.0V.
Set to FM 87.5MHz and check that the test
point is more than 0.5V.
5. FM Tracking Check
Settings : Test point : TP7(Lch), TP8(Rch)
Method : Set to FM 98.0MHz and check that the test point
is less than 9.0dBµV<U,LH>, 13dBµV<HS>.
6. AM IF Adjustment
Settings : Test point : TP7(Lch), TP8(Rch)
Adjustment location : L802
Input level : Variable
Method : Adjust L802 so that the output becomes max.
7. DC Balance / Mono Distortion Adjustment
Settings : Test point : TP4, TP5
(DC Balance)
TP7(Lch), TP8(Rch)
(Distortion)
Adjustment location : L801
Input level : 60dBµV
Method : Set to FM 98.0MHz and adjust L801 so that the
voltage between TP4 and TP5 becomes 0V ±
0.04V.
Next, check that the distortion is less than 1.3%
< DECK SECTION >
8. Tape Speed Adjustment (DECK 1, DECK 2)
Settings : Test tape : TTA100(3kHz)
Test point : TP9(Rch), TP10(Lch)
Adjustment location : SFR1
Method : Play back the test tape and adjust SFR1 so that
the frequency counter reads 3000Hz ±
5Hz(FWD) and ± 45Hz(REV) with respect to
forward speed.
9. Head Azimuth Adjustment (DECK 1, DECK 2)
Settings : Test tape : TTA300 (315/10kHz)
Test point : TP9(Rch), TP10(Lch)
Adjustment location : Head azimuth
adjustment screw
Method : Play back the 10kHz signal of the test tape
and adjust screw so that the output becomes
maximum. Next, perform on each FWD PLAY
and REV PLAY mode.
10. PB Frequency Response Check (DECK 1, DECK 2)
Settings : Test tape : TTA300 (315/10kHz)
Test point : TP9(Rch), TP10(Lch)
Method : Play back the 315Hz and 10kHz signals of the
test tape and check that the output ratio of the
10kHz signal with respect to that of the 315Hz
signal is within 0 ± 2dB.
11. PB Sensitivity Adjustment (DECK 1, DECK 2)
Settings : Test tape : TTA200 (400Hz)
Test point : TP9(Rch), TP10(Lch)
Adjustment location :
SFR301 (DECK 1, Lch)
SFR302 (DECK 1, Rch)
SFR303 (DECK 2, Lch)
SFR304 (DECK 2, Rch)
Method : Play back the test tape and adjust SFRs so that the
output level of the test points become
245mV±10mV.
12. REC/PB Frequency Response Adjustment (DECK 2)
Settings : Test tape : TTA602 (Normal)
Test point : TP9(Rch), TP10(Lch)
Input signal : 1kHz / 10kHz (LINE IN)
Adjustment location :
SFR351 (Lch)
SFR352 (Rch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at the test
points becomes 12.5mV. Record and play back the
1kHz and 10kHz signals and adjust SFRs so that the
output level of the 10kHz signals becomes 0dB ±
0.5dB with respect to that of the 1kHz signal.
13. REC/PB Frequency response Check (DECK 2)
Settings : Test tape : TTA-615 (CrO
2
)
Test point : TP9(Rch), TP10(Lch)
Input signal : 1kHz/10kHz (LINE IN)
Method : Apply a 1kHz signal and REC mode. Then
Adjust OSC attenuator so that the output level
at the test points becomes 12.5mV. Record and
play back the 1kHz and 10kHz signals and
check that the output is 0dB ± 2dB.
14. REC/PB Sensitivity Adjustment (DECK 2)
Settings : Test tape : TTA602 (Normal)
Test point : TP9(Rch), TP10(Lch)
Input signal : 1kHz (LINE IN)
Adjustment location :
SFR305 (Lch)
SFR306 (Rch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at the test
points becomes 125mV. Record the play back the
1kHz signal and adjust SFRs so that the output level
becomes 0dB ± 0.5dB.
< TUNER SECTION >
- 40 -
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48